Controls
Request for more detailed info.
Download the PDF Version of this page.
Overview
A Custom Built Cabinet for Your Specific Project The Command and Control Cabinet can be installed inside or outside in a water-resistant housing. It is recommended that this cabinet be installed within 200'-0" from the bollards.
The Command and Control Cabinet includes the following
- PLC.
- Variable Frequency Drives.
- Breakers.
- Low voltage transformer.
- Transaction counter.
- Switch for manual operation.
- Program for automatic operation.
- Power failure indicator.
- Manages Optional LED based traffic light (24 VAC).
- Capable for remote diagnosis via a modem connection.
- Vehicle detector bases (vehicle detector quantity optional).
- User manual.

Description
Sample Command Control Cabinet Description
- Differential breakers.
- Individual breakers.
- Thermostat.
- Power relay.
- Low voltage transformer.
- Fire siren sensor.
- PLC.
- Vehicle detector.
- Connector for vehicle detector.
- Counter.
- Power relay.
- Command relay.
- Manual command.
- Alarm acknowledgement.
- Failure light.
- Terminal blocks.
- Lights and outlet.
- Heating element.
- RF receptor.
Specifications
GENERAL CAPABILITIES OF CABINET
|
Separate Lane Capacity |
1 or 2 access points. |
| # of Bollards/Lane | 1 to 4 bollards per access point. |
| Distance from Bollards | Within 200'-0" from bollards. |
| Programming | Customized for each application. |
Dimensions
STANDARD COMMAND CONTROL CABINET DIMENSIONS
30" WIDE X 36" TALL X 10" DEEP.
OPTIONAL SIZED CABINET ARE AVAILABLE. CONTACT FACTORY.
Installations
INSIDE OR OUTSIDE (WATER-RESISTANT) INSTALLATION OPTIONS
The Command & Control Cabinet can be mounted inside a building, in a covered parking garage or outside in a special water-resistant housing.
The standard cabinet can be anchored to an interior wall or on a concrete pad. The conduits enter the cabinet through a large rectangular opening in the bottom of the cabinet. (See drawing below)
Please refer to the Installation Manual for additional information.

Optional Equipment
- Lightning Surge Protection.
- Ampermeter.
- Modem.
- Cabinet lights and outlet.
- Timer and clock.
- Dialer.
Picture